Operation Instructions for Cyclic Corrosion Test Chamber.

Hello, everyone! Today, let's talk about the Spring Tension Tester produced by Mikrosize. This is a highly precise and user - friendly professional device that can bring great convenience to your testing work. Before using this Spring Tension Tester, make sure to place the device steadily on a sturdy and level workbench. Then, connect the power supply and turn on the device switch. Wait for the device to complete the self - check. When the normal working interface is displayed on the screen, you can start the operation. First of all, according to the specifications of the spring to be tested, select appropriate measurement units and a range on the device's operation interface. This step is of great importance, as correct settings can ensure the accuracy of the measurement results. Next, open the spring fixing device and carefully and firmly install the spring to be tested in the designated position of the tester. Be sure that the spring is installed in place to avoid displacement or falling off during the test. After the installation is completed, close the spring fixing device and enter relevant parameters of the spring, such as model and material, in the operation interface, which is convenient for subsequent data recording and analysis. When everything is ready, click the "Start Test" button. The Spring Tension Tester will automatically apply tension to the spring and simultaneously monitor and record the force situation and deformation data of the spring in real time. During the test, pay close attention to the operating status of the device and the data displayed on the screen. If abnormal situations occur, such as unusual noises from the device or excessive data fluctuations, immediately press the "Emergency Stop" button to stop the test and check the reasons. After the test is completed, the device will automatically calculate and display key data such as the tension value and elastic coefficient of the spring. At this time, open the spring fixing device, carefully take out the tested spring, and record the test data. During use, regularly clean and calibrate the Spring Tension Tester to ensure that the device always maintains good working conditions and measurement accuracy. After each use, turn off the power supply of the device, clean the workbench, and store the device properly. I believe that through such a clear and standardized operation process, you will be able to skillfully use Mikrosize's Spring Tension Tester to efficiently and accurately complete the spring tension testing work.


Home
Copyright ©️ 2023 Mikrosize All rights reserved.     Sitemap