Product Feature:
● The sulfur dioxide salt spray tester is suitable for corrosion testing of metal material protection, parts, electronic devices and industrial products, and can quickly and conveniently reproduce the corrosion process of metal surfaces after spraying and without treatment.
● It can meet the test requirements of GB9789-1988 "Metallic and other non-metallic organic coatings - Sulfur dioxide corrosion test under typical condensation conditions" and related standards for various corrosion gas tests.
● The standards this equipment complies with are: GB/T2423.17-2008/1EC 60068-2-11-1981 ASTM.B117-2009 JIS H8502 GB/T10125-2012/1SO 9227-2006 GB-T5170.8-2008 GB/T5170.11-2008 GB/T10587-2006 GB/T2423.33-2005 DIN 50188-1997.
Product Application:
● This test equipment simulates corrosion tests in artificial environments, suitable for determining the adaptability of electrical and electronic products and their materials for use under chemical corrosion conditions and for comparing the quality of metal materials with or without corrosion protection.
● It is suitable for corrosion testing for the rapid analysis of discontinuities, pores and damage in organic and inorganic coatings.
Availability: | |
---|---|
Quantity: | |
Product Description
Technical Specification:
Name | Sulfur Dioxide Salt Spray Testing Machine | ||
Model | ASR-60SO2 | ASR-90SO2 | ASR-120SO2 |
Internal Dim. (mm) ( W * D * H)
| 600x450x400 | 900x600x400 | 1200x1000x500 |
External Dim. (mm) ( W * D * H)
| 1900x750x1460 | 2200x950x1460 | 2500x1270x1460 600 |
Laboratory Volume(L) | 108 | 216 | 300 |
Laboratory Temperature | Saltwater test method(NSS ACSS)35℃±1℃ Corrosion Resistance Test Method(CASS)50℃±1℃ | ||
Pressure Tank Temperature | Saltwater test method(NSS ACSS)47℃±1℃ Corrosion Resistance Test Method(CASS)63℃±1℃ | ||
PH Value | Saltwater test method 6.5-7.2 Corrosion Resistance Test Method3.0~3.2 | ||
Saltwater Concentration | The concentration of sodium chloride solution is 5% or 0.26 grams of copper chloride is added per liter of sodium chloride solution with a concentration of 5%. | ||
Sulfur Dioxide Concentration | 0.05~1% (Adjustable) | ||
Gas Generation Mode | Cylinder method | ||
Spray Volume | 10~2.0mV80cm²/h(The standard requires 16 hours of testing for an average quantity) | ||
Spray Method | Continuous/Intermittent spray (optional) | ||
Compressed Air Pressure | 1.00±0.01Kgf/cm² | ||
Power Supply | AC220±10V | ||
Laboratory Temperature Range | RT~50℃ | ||
Pressure Tank Temperature Range | RT~63℃ | ||
Temperature Deviation | ±0.5℃(Measure after the temperature sensor stabilizes for 30 minutes.) | ||
Temperature Distribution Uniformity | ±1℃;(The measurement must be made at a distance of 1/6 of the wall surface of the test area and after the temperature has stabilized for 30 minutes.) | ||
Heating Time | From indoor temperature to 50°C, within 40 minutes (under no-load condition) | ||
Maximum Capacity of Medicine Tank | 25L | ||
Spray Volume | 1~2m1/80cm2/h(The standard requires 16 hours of testing for an average quantity) | ||
Spray Pressure | 1.00±0.01kgf/cm2 | ||
Spray pH Value | Neutral:6.5~7.2 Acidity:3.0~3.3 | ||
Sulfur Dioxide Gas Concentration | Sulfur dioxide gas concentration:0.05%~1%According to the total volume of the test chamber including the sloping roof of 405L, the calculated addition range is 0.2L~4.05L(Adjustable) | ||
Sulfur Dioxide Gas Filling Pressure | 0.5~1kgf/cm2 |
Packing List:
Name | Quantity |
Plastic Bucket(13L) | 1 pc |
Exhaust Pipe Connector | 1 set |
Hose Clamp | 4 pcs |
Measuring Cup | 1 pc |
V-shaped Sample Rack | 1 set |
O-shaped Sample Rack | 1 set |
Connecting Pipe | 1 set |
PH Test Paper | 1 pack |
Sodium Chloride | 2 bottles (500 grams/bottle) |
Air Blast Atomizer | 1 set |
Fog Collector | 2 pcs |
Fog Collecting Cylinder | 2 pcs |
Equipment Factory Test Report | 1 copy |
Equipment Packing List | 1 copy |
Equipment Electrical Schematic Diagram | 1 copy |
Instruction Manual | 1 copy |
Product Certificate | 1 copy |
Warranty Card | 1 copy |