Product Feature:
● The inner and outer boxes are made of Class A grey PVC that is resistant to high temperature, high humidity and high corrosion, and is suitable for various test specifications such as salt water spray and copper acetate.
● The automatic or manual water adding system is used, which has the function of automatic or manual water replenishment when the water level is insufficient. The experiment is not interrupted, meeting the diversified environmental requirements of guests.
● The spray tower is equipped with a conical disperser, which has the functions of guiding the mist, adjusting the mist volume, and evenly falling the mist.
● The salt spray test uses direct steam heating, which has a fast heating speed, uniform temperature distribution and shortened standby time.
Product Application:
● The salt spray test machine is for a variety of material surface treatment, including coating, electroplating, organic and inorganic skin film, anodic treatment, anti-rust oil and other anti-corrosion treatment after testing its corrosion resistance, so as to establish the quality of the product.
Availability: | |
---|---|
Quantity: | |
Product Description
Technical Specification:
Item | Parameter | ||
Specification | Internal Dim. (mm) | 600×450×400mm ( W * D * H) | |
External Dim. (mm) | 1000×600×1100mm ( W * D * H) | ||
Power Supply | Single-phase 220V 2KW 50H | ||
Technical Base | Salt Spray Test:NSS,ACSS | Laboratory | 35℃ ± 1℃ Fluctuation:≤±0.5℃ Uniformity: ≤2℃ |
Saturated Air Tank | 47℃ ± 1℃ | ||
Corrosion Resistance Test:CASS | Laboratory | 50℃±1℃ Fluctuation:≤±0.5℃ Uniformity: ≤2℃ | |
Saturated Air Tank | 63℃ ± 1℃ | ||
Body Structure |
Using Materials | a. The test machine box is made of light grey impact-resistant PVC board with a thickness of 5mm and a service temperature of 85℃. | |
b.The laboratory cover seal is made of PVC impact-resistant plate with a thickness of 5mm, which will not be distorted when used at high temperatures. | |||
c.The hidden integrated reagent refill bottle is easy to clean and operate. | |||
d.The saturated air barrel adopts SUS#304 stainless steel high pressure barrel with the best insulation effect (Taiwan Electric Heating) | |||
e. The sample placement table is made of 8mm heat-resistant ABS board with strong load-bearing capacity. | |||
Spray System | a. Bernaut principle is adopted to absorb brine and then atomize, atomizing degree is uniform. | ||
b. Nozzle: Made of special glass, it can adjust the size of the spray amount and the spray angle. | |||
c. Spray volume1~2ml/h (adjustable) The standard requires 16 hours of testing for an average quantity | |||
d. Spray method: Continuous spray | |||
Air Supply System | A section for rough adjustment: 2Kg/cm2,Imported air filters come with a drainage function. | ||
The second stage is for precise adjustment of 1Kg/cm2, 1/4 pressure gauge, showing precise accuracy. | |||
Heating System | Using direct heating, when the temperature reaches the set point, it automatically switches to a constant temperature mode, with precise temperature control and low power consumption. | ||
Control System | a. The laboratory and pressure barrels both use liquid crystal dual-number digital temperature controllers with a control error of ±1.0℃ | ||
b. Laboratory heating tank uses liquid expansion safety temperature controller 0~120℃ | |||
c. Liquid crystal digital time controller with power outage memory function 0.1S~999hr | |||
d. Timer 0~99999 hr | |||
e. Relay | |||
f. Toggle switch with light, can work continuously for 25,000 times. |
Packing List:
Item | Quantity |
Analysis Pure (NACL)500 Grams | 2 bottles |
Medication Preparation Barrel | 1 pc |
V-shaped Shelf | 4 pcs |
O-shaped Storage Rod | 6 pcs |
Standard Measuring Cylinder | 1 pc |
Mist Collector 80cm2 | 1 pc |
Tempered Glass Nozzle (replace after 5000H) | 1 pc |
Dehumidification System | 1 set |
Instruction Manual | 1 copy |
Product Certificate | 1 copy |
Warranty Card | 1 copy |