MS-GDW-10KN Microcomputer Controlled High and Low Temperature Electronic Universal Testing Machine

Product Features:

Project

Description

Air Conditioning System

In the case of continuous operation of the refrigeration system, the central control system amplifies the collected temperature and humidity signals in the box, converts them to analog/digital, and compares them with the set value of temperature and humidity (the target value) after nonlinear correction. The deviation signal obtained is calculated by PID, and the adjustment signal is output. Automatically control the output power of the heater, and finally make the temperature in the box reach a dynamic balance.

Air Circulator

Air circulation device: built-in air conditioning room, circulating air duct and long-axis centrifugal fan, the use of efficient refrigerator and energy regulation system, through the efficient fan for effective heat exchange, to achieve the purpose of temperature change. By improving the air blast flow, the air flow rate and the heat exchange ability between the heater surface and the air are improved, and the temperature uniformity of the test chamber is greatly improved through the adjustment of the air outlet.

Type of Heating

High quality nickel-chromium alloy electric heater;

Type of Cooling

Multistage diaphragm type air heat exchanger;

Availability:
Quantity:
  • MS-GDW-10KN

  • Mikrosize

Product Description

Technical Specifications:

Prduct Name

Microcomputer Controlled High and Low Temperature

Electronic Universal Testing Machine

Model

MS-GDW-10KN(-20℃~150℃)

Subdivision Model

-5KN

-10KN

Capacity

 

KN

5

10

KG

500

1000

lb

1102

2204

Sensor

America

Servo Motor

Panasonic of Japan

Unit Switching

G,Kg,lb,N,KN

Displacement Unit Switching

Inch  cm  mm

Testing Machine Class

0.5 Class

Effective Force Measurement Range

0.2%~100FS

Force Accuracy

Within ±0.5% of the indicated value

Force Resolution

1/500000

Displacement Resolution

≤0.05μm

Displacement Accuracy

Within ±0.5% of the indicated value

Deformation Measuring Range

0.2%100%FS

Precision of Deformation Indication

Within ±0.5% of the indicated value

Large Deformation Measuring Range

1000mm (optional)

Large Deformation Resolution

0.01mm (optional)

Error Limit of Large Deformation Indication

Within ±0.5% of the indicated value (optional)

Maximum Test Speed

500mm/min; The maximum value is 1000mm/min

Minimum Test Speed

0.01mm/min

Velocity Accuracy

Within ±0.5% of the indicated value

Beam Travel/Measuring Height

Test stroke without fixture: 1330mm; Test stroke with fixture: 800mm

Effective Width

750mm

Fixture Configuration

One set of film stretching fixture, one set of 180 degree stripping fixture

Return Mode

Manual or automatic

Stop Method

1.The maximum break value automatic stop 2.The upper and lower limit safety setting stop

Safety Device

1.Mechanical stroke switch protection 2.Emergency stop switch emergency braking

Overload Protection

Over 100% of the load, the machine automatically protects

Packing List

 

1 power cord; 1 test software program; 1 data cable; 1 copy of manual; 1 certificate

Optional Accessories

Anti-splash device (protective door); Computer; Printer; Small deformation metal extensometer, large deformation extensometer

Power Supply

220V.AC/ 50HZ; (110V.AC/60HZ can be selected by country)

Mainframe size/weight

Model with base: L* W* H:800mm*750mm*2100mm/about 205KG


Refrigerating System

Project

Description

Refrigeration Compressor

The "French Taikang" compressor is used to form the refrigeration system. Compared with the same type of refrigeration compressor, this type of compressor has large refrigeration capacity, low noise, low energy consumption and high efficiency. Capable of long-term, stable and reliable operation. It greatly reduces the cost of the user, is conducive to reducing the noise of the equipment, extending the service life of the equipment, and improving the economy of the use of the equipment.

Working Principle of Refrigeration

Both the high and low refrigeration cycles adopt the inverse Carro cycle, which consists of an isothermal process and an adiabatic process. The process is as follows: the refrigerant is adiabatic compressed to a higher pressure by the compressor, and the work is consumed to increase the exhaust temperature, and then the refrigerant is isothermal exchanged with the surrounding medium through the condenser to transfer heat to the surrounding medium. After the refrigerant through the closure valve adiabatic expansion to do work, then the refrigerant temperature decreases. Finally, the refrigerant absorbs heat from the higher temperature object isothermal through the evaporator, so that the temperature of the cooled object is reduced. This cycle is repeated to achieve the purpose of cooling.

Refrigerated Evaporator

Single side welding, cold expansion;

Type of Cooling

Air-cooled

Main Refrigeration Parts

Compressors, solenoid valves, filters, etc

Refrigerating Fluid

Adopt environmentally friendly refrigerant R404A

The ozone loss coefficient ODP value is 0

 

safety protection

The test box meets the national electrical safety standards and wiring specifications, and each wiring port is clearly marked without exposure;

The studio is absolutely insulated from each power source, safe and reliable;

Complete safety protection function (as follows);

A. Reliable grounding protection device

B. The whole power leakage/break/phase loss/overvoltage/undervoltage protection

C. Studio overtemperature protection

D. Refrigeration compressor overpressure protection

E. Refrigeration compressor overload protection


Conditions of use

PROJECT

Description

Voltage

single-phase line system 220VAC±10%;

The ambient temperature

535℃

Ambient humidity

≯85%R.H

Atmospheric pressure

86106Kpa

 

Environmental conditions

There is no strong vibration, no strong electromagnetic field interference, no high concentration dust and corrosive substances, no direct sunlight or direct radiation from other heat sources around the equipment site

The equipment should be placed horizontally in a well-ventilated test room with sufficient space around it for operation and maintenance.

 

Product Application:

This series of electronic universal testing machines is a classic and practical model developed by our company, and it is currently the mainstream model in production.

 Drawing on Japanese technology and based on several previous generations of models, our company has undergone multiple rounds of new upgrades and design developments.

Both the mainframe structure and the measurement and control system have undergone significant technological upgrades, resulting in a more rational structure and enhanced functionality.

This series represents the leading edge of technology in the industry and is a new generation of electronic universal testing machines. With over 1000 units produced, this series has undergone extensive practical testing and continuous improvement.

Its technology and craftsmanship are mature, with high reliability and low failure rates, making it highly praised and welcomed by the market and users.

The testing machine adopts a high-precision, stable-performance digital AC servo speed control system and servo motor from Panasonic, Japan, as the driving system.

The specially designed synchronous toothed belt reduction system and ball screw assembly drive the movement of the machine's movable beam.

Using Windows as the operating platform, the control and data processing software based on database technology allows for the display of test force, peak test force, beam displacement, specimen deformation, and test curves on the screen.

All test operations can be completed on the computer screen with mouse inputs, providing an excellent human-machine interface and ease of operation.

The independent dual-channel fully digital program-controlled amplifier achieves true physical zero adjustment, gain adjustment, and automatic range switching, zeroing, and calibration of test force measurements.

It eliminates all analog adjustment components, with highly integrated control circuits, completely removing potentiometers and other mechanical adjustment devices. This ensures a simple structure and reliable performance.

The machine can achieve closed-loop control of parameters such as test force, specimen deformation, and beam displacement. It can perform tests under constant force, constant displacement, constant strain, constant rate load cycling, and constant rate deformation cycling. Users can independently set control modes like constant stress, constant strain, and constant displacement using the PC expert system. Smooth, disturbance-free switching between various control modes is possible.

The system can process data in accordance with multiple standards, including GB, ISO, JIS, ASTM, and DIN. Notably, it has excellent scalability, with results that can be stored on disks in ASCII format, facilitating further data analysis, database management, and network transmission for post-processing.

This series of electronic universal testing machines is powerful and versatile. It can be used for testing the mechanical properties of various metals, non-metals, and composite materials, such as tensile, compression, bending, shearing, peeling, tearing, extraction, and ring stiffness.

It is suitable for mechanical testing of metal materials like metal wire, metal foil, metal sheet, and metal rod, as well as non-metal materials like plastic pipes, plastic profiles, waterproof membranes, geotextiles, wires and cables, textiles, fibers, rubber, ceramics, concrete, adhesives, food and pharmaceutical packaging, films, wood, and paper.

The machine can be widely applied in manufacturing industries such as machinery manufacturing, vehicle manufacturing, aerospace, petrochemicals, wires and cables, paper, textiles, construction, and building materials. It is also ideal for quality supervision and inspection departments, research institutes, and for teaching and demonstrations in colleges and universities.

For non-metallic material testing, the large testing space, wide speed range, and diverse fixture configurations can meet various non-metallic material testing requirements. A variety of optional test fixtures and test standards can accommodate different material tests, achieving a multi-functional effect with a single machine.

  

Main Configuration:

Product Name

High and low temperature test chamber

 

 

Main Configuration

Chamber Body

Structural Form

Integrated, test box and controller, refrigeration unit respectively installed.

Shell Material

Stainless steel plate SUS304 1.0mm

Working Chamber  Material

Stainless steel plate SUS304 1.0mm

Thermal Insulation Material

Hard polyurethane foam, insulation layer thickness 80mm

Instrument Connection

The upper and lower center of the box is open Φ80*2

Guiding Track Bracket

Guide rail for high and low temperature Chamber

Customize the size according to the main device

Control

System

Temperature Controller

Single point temperature controller

Temperature Control Performance

Temperature resolution: ±0.1℃;

Temperature probe

Class A high precision industrial platinum thermal resistance PT100

Run Mode

constant

Main actuator

Schneider AC contactor, thermal relay; Small relay; Transformer; Solid state relay, etc.;

Compressor refrigeration system

Compressor

Refrigeration compressor

Solenoid valve

Japan "Egreomiya" original import

Device for drying and filtering

Denmark "Danvers" original import

copper pipe

High quality oxygen free copper pipe, nitrogen filled welding

Energy regulated expansion valve

Denmark "Danvers" original import

evaporator

Self-designed domestic high quality and efficient fin type

Type of cooling

Forced air cooling

Installation characteristics

A, the whole refrigeration system is filled with nitrogen pressure 2.2Mpa leak test;

B, heating, cooling system is completely independent

C, equipped with the company's characteristics, high temperature refrigerator return air cooling system;

D, all refrigeration system action program, completely automatic control by the instrument.

Heating system

Temperature control element

solid state relay

Heating Mode

High quality nickel chromium wire electric heater

Air-blast system

Circulatory system

Fan forced convection mode

Electrical motor

Extended stainless steel shaft motor

Fan blade

Centrifugal blade

Vibration mitigation

Compressor

Special rubber damping

Safety device

Safety alarm action

Sound and light alarm tips

Test chamber structure

Ground protection

Test chamber

Independent over-temperature protection system

Compressor

Over-voltage protection/ over-temperature protection/overload protection

Power Supply

Over-current/leakage protection

Accessories

1 power cord;

Document

Warranty card/Product certificate/instruction manual.

 

High and low temperature Chamber parameters (compressor refrigeration)


Ø Chamber size: 400 x 400 x 700(mm) (D x W x H) size can be customized according to the equipment

Ø Dimensions: 600×1380×1640(mm) (D×W×H) dimensions can be customized according to the equipment

Ø Temperature range: -20 ° C to +150 ° C

Ø Temperature change: Temperature rise: -20℃ ~ +150℃ 1 ~ 3℃/MIN

Ø Temperature reduction: 0℃ ~ -20℃ 1℃/MIN

Ø Control accuracy: ≤±1℃

Ø Temperature fluctuation: ≤2 ° C