Availability: | |
---|---|
Quantity: | |
Product Description
Technical Specification
Model | ATH 072TR-(+10) -B
| ATH 162TR-(+10) -B |
Internal Dim. W*H*D(mm) | 400x400x450 | 600x450x600
|
External Dim. W*H*D(mm) | 1060x1760x780
| 1260x1910x830
|
Temperature Range
| -40℃-+100℃
| |
Relative Humidity Range
| 30%~95%RH
| |
Temperature and Humidity Fluctuation | +(-)0.3℃;+(-)3%RH
| |
Temperature and humidity Uniformity | +(-)0.5℃;+(-)5%RH
| |
Indication Resolution | 0.1℃;0.1%RH
| |
Heat up Time(min)
| 30
| |
Pull down Time(min)
| 40 | |
Temperature variability | Heating rate: -40℃~+100℃ ≥2~3℃/min (No-load nonlinearity) Cooling rate: +100℃~-40℃ ≥0.7~1.0℃/min (No-load nonlinearity) Meet PV1200, 2005A, PR308.2 standard curve
| |
Exterior Chamber Material
| Stainless steel piate+ Powder Coated
| |
Inner Chamber Material
| SUS# 304 stainless steel plate
| |
Insulation Material
| PU& Fiberglass wool
| |
Circulation System
| Siroco fan
| |
Heating System
| SUS# 304 stainless steel high-speed heater
| |
Cooling System | Airtight compressor +evaporator fins+ air-cooling condenser
| |
Dehumidification System | ADP Critical dewpoint cooling/dehumidifying method
| |
Controller System | Digital electronic indicators+ S.S.R. with PID automatic calculation capability
| |
Other Components | Control status indicator lights Vacuum glass inspection window& chamber lamp Experiment separation shelves (freely adjustable 6pcs)
| |
Safety Devices | Overheating prevention circuit-breaker, compressor overload protection, control system overload protection,humidifying system over heading drying out prevention, breakdown indicator light
| |
Power Supply
| AC 1f220V;60/50Hz
| |
7.5 | 9 |